Part Number Hot Search : 
NTE2354 1BAIR2 908E624 C1302 07D390K 2SC50 MA3X704E ASM63
Product Description
Full Text Search
 

To Download NCT2DC12V Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 NCT
17.4x14x13.51C: 17.4x7.2x13.5 Features
Ultra small size, light weight. Low coil power consumption. Forward/reverse motor control is possible with a single relay. PC board mounting. Suitable for automobile, automation system, electronic equipment.
Ordering Information
NCT 2
1 2
DC12V
3 3 Coil rated Voltage(V)DC:12
1 Part numberNCT 2Contact arrangement1:1C2:2x1C5:2C
Contact Data
Contact Arrangement Contact Material Contact Rating (resistive) Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operation Electrical life Mechanical 1C SPDT(B-M) 2C DPDT(B-M) 2y1C 2ySPDT(B-M) H-Bridge Silver alloy Ag SnO2 NO 20A/14VDC NC 10A/14VDC 300W 16VDC Max. Switching Current:20A 100m (200mV at 10A) Item 3.12 of IEC255-7 105 Item 3.30 of IEC255-7 107 Item 3.31 of IEC255-7
Coil Parameter
Coil voltage VDC Rated 012-800 12 Pickup voltage VDC(max) (60%of rated voltage ) 7.2 release voltage VDC(min) (8% of rated voltage) 1.0
Dash numbers
Operating Voltage Range VDC 10-16
Coil resistance 10%
Coil power consumption W
Operate Time ms
Release Time ms
180
0.8
10
10
CAUTION: 1.The use of any coil voltage overstep operating voltage range of coil , it will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
127
www.dblectro.com
NCT
Operation condition
Insulation Resistance Dielectric Strength Between contacts Between contact and coil Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass 100M min (at 500VDC) Item 7 of IEC255-5 Item 6 of IEC255-5 (Detection current:10m A) Item 6 of IEC255-5 (Detection current:10m A) IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-21 Test Ua1 IEC68-2-20 Test Ta method 1 IEC68-2-3Test Ca
50Hz 500V 50Hz 500V Functional 100m/s2 11ms; Survival 1000 m/s2 6ms 10~100Hz 44 m/s2 10N 235x2 3x0.5s -40~85 85% (at 40) 8g,4g (1C )
Qualification inspection:
Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24.
Dimensions (Unit: mm) mm 0.3 0.4 0.65 0.8 1.0 1.1 1.25 1.4 1.45 2.5 3.15 3.5 4.3 6.0 6.8 7.2 9.5 13.5 14 15 17.4
>acCa
Dimensions
Mounting (Bottom views)
0.012 0.016 0.026 0.031 0.039 0.043 0.049 0.055 0.057 0.098 0.124 0.138 0.169 0.236 0.268 0.283 0.374 0.551 0.551 0.591 0.685
Wiring diagram (Bottom views)
NOTES 1).Dimensions are in millimeter.
2).Inch equivalents are given for general information only.
www.dblectro.com


▲Up To Search▲   

 